Blackouts suppress alert notifications during planned maintenance windows. Administrators create blackouts to prevent false alerts while performing database upgrades, schema changes, or infrastructure work. The AI DBA Workbench supports both one-time blackouts and recurring schedules.
Scopes
Blackouts operate at four hierarchical levels. A blackout at any level suppresses alerts for everything beneath the blackout in the hierarchy.
The following table describes the available scopes:
| Scope | Target | Description |
|---|---|---|
| Estate | Entire installation | Suppresses alerts for all servers across all groups and clusters. |
| Group | Cluster group | Suppresses alerts for all clusters and servers within the group. |
| Cluster | Single cluster | Suppresses alerts for all servers within the cluster. |
| Server | Individual server | Suppresses alerts for only the specified server. |
The system enforces scope validation when creating or updating a blackout. Estate blackouts must not reference any group, cluster, or server. Group blackouts require a group identifier. Cluster blackouts require a cluster identifier. Server blackouts require a connection identifier, and the datastore refuses a server blackout without one.
One-Time Blackouts
Administrators create one-time blackouts through the admin panel or the REST API. The admin panel offers two timing modes for scheduling a blackout.
The Start Now mode begins the blackout immediately. The administrator selects a duration preset or enters a custom duration. The following duration presets are available:
- A 30-minute window covers brief maintenance tasks.
- A 1-hour window covers standard maintenance tasks.
- A 2-hour window covers extended maintenance tasks.
- A 4-hour window covers major upgrade procedures.
- An 8-hour window covers full migration operations.
The Schedule Future mode activates the blackout at a specified start time. The administrator picks a start time and an end time for the maintenance window.
The following table describes the fields for a one-time blackout:
| Field | Required | Description |
|---|---|---|
| Scope | Yes | The level at which to suppress alerts. |
| Group / Cluster / Server | Conditional | The target entity; depends on the selected scope. |
| Reason | Yes | A description of why the blackout is needed. |
| Start Time | Yes | When the blackout begins. |
| End Time | Yes | When the blackout ends; must be after the start time. |
Administrators can stop active blackouts early using the Stop button in the admin panel.
Recurring Schedules
Recurring schedules automatically create blackouts at regular intervals. The alerter evaluates enabled schedules every minute and creates blackout entries when cron expressions match the current time.
The following table describes the fields for a recurring schedule:
| Field | Required | Default | Description |
|---|---|---|---|
| Name | Yes | -- | A human-readable name for the schedule. |
| Scope | Yes | -- | The level at which to suppress alerts. |
| Cron Expression | Yes | -- | A standard five-field cron expression. |
| Duration | Yes | -- | How long each blackout lasts, in minutes. |
| Timezone | No | UTC | The IANA timezone for cron evaluation. |
| Reason | Yes | -- | The reason recorded on each created blackout. |
| Enabled | No | true | Whether the schedule is active. |
Cron Format
A cron expression consists of five fields that represent minute, hour, day of month, month, and day of week. The following examples demonstrate common scheduling patterns:
0 2 * * *triggers daily at 2:00 AM.0 3 * * 1-5triggers on weekdays at 3:00 AM.0 4 * * 0,6triggers on weekends at 4:00 AM.0 1 * * 0triggers weekly on Sunday at 1:00 AM.0 0 1 * *triggers monthly on the first day at midnight.
Navigator Indicators
The Cluster Navigator displays blackout status on affected nodes in the navigation tree. An amber pause icon appears on servers, clusters, and groups that have an active blackout.
The icon appears at full opacity for direct blackouts. The icon appears at reduced opacity for inherited blackouts. Hovering over the icon shows whether the blackout applies directly or through inheritance from a parent scope.
Alert Suppression
The alerter checks for active blackouts before firing any alert. The following steps describe the suppression process:
- The alerter identifies the target server for the alert.
- The alerter checks for an active blackout at the server scope.
- The alerter walks up the hierarchy through cluster, group, and estate scopes.
- If any active blackout matches at any level, the alerter suppresses the alert.
- Suppressed alerts do not fire and do not generate notifications.
- When the blackout ends, normal alert evaluation resumes.
Permissions
The manage_blackouts permission controls access to
blackout management operations. Administrators with
this permission can create, update, delete, and stop
blackouts. All authenticated users can view the
blackouts on the connections they can see, regardless
of their permissions.
A blackout or blackout schedule on a cluster or a group silences alerts on every connection in it, so changing one requires you to see every one of those connections; seeing one of them is enough to view it. An estate blackout or schedule silences alerts on every connection, so creating, changing, stopping, or deleting one requires you to see every connection, although every user can view it. Superusers, and users granted access to all connections, see every connection.
The check runs when you make the change. A connection added to a cluster or group later is silenced by any blackout or schedule already on that cluster or group, and the check and the change do not run in a single transaction, so a connection that joins a cluster or group whilst the change is being made is also covered.
Related Documentation
- Alerts describes the alert lifecycle and management features.
- Alert Rule Reference lists all built-in alert rules.